| Page [2] |
 |
|
For dependable
operation of low air pressure warning systems. Sealed contact design
prevents shorts caused by dirt in brake system.
Normally "ON" |
|
G-8640 |
$3.65 |
Self Grounding
Contacts close as pressure drops into range 70-50 PSI
1 #8-32 stud terminal with hex nut and lock washer
1/4-18 dryseal thread
Overall size: 2" L x 1 1/16" hex. |
|
 |
|
|
G-9253 |
$6.96 |
Two positions
Normally "ON" (contacts closed(
Contacts open at rising vacuum; contacts close at lowering vacuum
Operates at 9 to 12 inches of mercury
Mounting stem: 1/8" - 27 dryseal thread, 11/32" long.
|
|
 |
|
|
G-M-705 |
$0.00 |
Four positions: Off-On Bat. # 1 - on Bat. #
1 & 2 - On. Bat #2
Ratings:
Continuous duty - 175 Amps
Intermittent duty - 325 Amps |
|
 |
|
S.P.S.T. (Off - On) Two
Stud Terminals
Disconnects battery circuit only. Does not disconnect alternator or
generator field circuit. When used on alternator equipped vehicle, engine
should be stopped before switching to "Off" position to prevent
possible alternator diode failure. Wiring diagram included. |
|
G-2484 |
$17.15 |
12 & 6 Volts
Heavy steel case, plated; die cast lever
Two 3/8" brass terminals and hex nuts with lock
washers
Brass mounting stem: 3/4" dia., 25/32: long; two hex
nuts and lock washers
Overall length: 4 1/8", body diameter 2 5/8" |
|
G-2484-A |
$19.04 |
36 & 24 Volts
Same as G-2484 except with silver laminated contacts |
|
 |
|
D.P.S.T. (Off - On)
Four Stud Terminals
Disconnects battery circuit and alternator or generator field circuit.
Electrical contacts are arranged to interrupt field circuit before battery
circuit is broken. Recommended for gasoline and oil tank trucks. Wiring
diagram included. |
|
G-75903 |
$20.31 |
12 & 6 Volts
Heavy steel case, plated; chromed die cast lever
Two 3/8" and two #10-32 brass stud terminals and hex nuts with lock
washers
Brass mounting stem: 3/4" dia., 25/32: long; two hex
nuts and lock washers
Overall length: 4 1/8", body diameter 2 5/8" |
|
G-75904 |
$23.28 |
36 & 24 Volts
Same as G-75903 except with silver laminated contacts |
|
 |
|
| For buses, trucks,
passenger cars, industrial vehicles and other motorized equipment. Typical
applications: Bus "DOOR" open warning. Back-up warning, Bus
Operator Signal, low air pressure warning. |
|
G-4099(12 Volt) |
$7.52 |
|
G-40151(24 Volt) |
$8.81 |
Replaces:
Ford FDM-2938
GMC 116882
Superior Coach 76032
Divco-Wayne E-11811A |
|
 |
|
|
G-40100 |
$15.46 |
Extra Heavy Duty
S.P.S.T., 2 positions
Normally "Off" - pull to "On" - spring
return to "Off" position.
For up to 36 Volt Applications |
|
| Page [2] |